Guide

Testing updates yourself

Trying updates, going back and the automatic fallback with a test kit.

Each test round comes with the installer ISO and two update files, so you can try updating, going back and the automatic fallback on a real PC. They are signed with the same build’s key as the ISO, so a PC installed from that ISO accepts them.

File What it is
asimaos-V1-x86_64.iso The version to install, for example 2026.11.18.1
asimaos-V2-x86_64.aosupd The same system as a newer version (…2): a good update
asimaos-V3-x86_64.aosupd A newer version again (…3) whose login screen never starts, made broken on purpose

The automated test does the same in a virtual machine: testbed/boot-test.py --iso --update V2 V3.

1. Install

Install V1 from the USB stick. Copy both update files to a USB drive or to your home folder.

2. A good update

  1. Open Asima Updater and choose …V2.aosupd (or double-click it in Dolphin). It checks the signature and every part first; then Install.
  2. Restart. The start menu shows Asima OS V2 (current) and Asima OS V1 (backup).
  3. V2 starts. After about a minute (the login screen has to stay up for 15 seconds), it counts as good. Asima Updater → Versions shows it.

3. Going back

  1. Asima Updater → Versions → V1 → Start it once. Restart: V1 starts this one time; the next restart is V2 again.
  2. Versions → V1 → Make it the current version. Now V1 starts every time, and V2 is the backup.
  3. Make V2 current again the same way.

In a terminal: asimaos versions, asimaos use V1 --once, asimaos use V2.

4. A broken update goes back by itself

  1. Install …V3.aosupd like V2 and restart.
  2. V3’s login screen never starts. Do nothing: after a few minutes the PC restarts by itself (the health check fails), tries V3 three times, then starts V2 on its own.
  3. V2 is current again; Asima Maintenance → Health lists the failed starts of V3 and why.

5. What else to try on real hardware

  • A power cut (pull the plug) in the middle of installing an update: the old version must start, and installing the same file again must finish it.
  • Asima Rescue (start menu → Asima Rescue): unlock the disk, reinstall the running version from its update file on a USB drive.
  • Repair: start the USB stick, open Install Asima OS and choose Repair an installed Asima OS (in a terminal: sudo /run/initramfs/live/asimaos/asimaos-repair).
  • Secure Boot with the blue approval screen (MokManager), TPM unlock (Asima Maintenance → Security), NVIDIA drivers with lockdown, face and fingerprint sign-in.

Write down what you see, or make a problem report in Asima Maintenance → Health and save it.